{"id":4652,"date":"2023-09-08T14:32:00","date_gmt":"2023-09-08T12:32:00","guid":{"rendered":"https:\/\/measline.com\/?post_type=project&#038;p=4652"},"modified":"2023-09-11T08:42:04","modified_gmt":"2023-09-11T06:42:04","slug":"the-ht-irs-01-reactor-for-spectroscopic-studies","status":"publish","type":"project","link":"https:\/\/measline.com\/index.php\/en-gb\/project\/the-ht-irs-01-reactor-for-spectroscopic-studies\/","title":{"rendered":"The HT-IRS 01 Reactor for spectroscopic studies"},"content":{"rendered":"\n[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; background_color=&#8221;rgba(0,0,0,0.05)&#8221; custom_margin=&#8221;0px|0px|0px|0px|false|false&#8221; custom_padding=&#8221;0px|0px|0px|0px|false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px||0px||true|false&#8221; custom_padding=&#8221;11px||3px||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_button button_url=&#8221;@ET-DC@eyJkeW5hbWljIjp0cnVlLCJjb250ZW50IjoicG9zdF9saW5rX3VybF9wYWdlIiwic2V0dGluZ3MiOnsicG9zdF9pZCI6IjQ0MzkifX0=@&#8221; button_text=&#8221;Back to subcategory&#8221; _builder_version=&#8221;4.22.1&#8243; _dynamic_attributes=&#8221;button_url&#8221; _module_preset=&#8221;default&#8221; custom_button=&#8221;on&#8221; button_text_color=&#8221;#225500&#8243; button_border_width=&#8221;0px&#8221; button_icon=&#8221;&#x4a;||divi||400&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_button][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row column_structure=&#8221;1_2,1_2&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/measline.com\/\/wp-content\/uploads\/2022\/01\/reaktor.jpg&#8221; title_text=&#8221;reaktor&#8221; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; width=&#8221;63%&#8221; module_alignment=&#8221;center&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;2px|||||&#8221; global_colors_info=&#8221;{}&#8221;]<h1 align=\"justify\" style=\"text-align: left;\"><strong>The HT-IRS 01 Reactor <\/strong><strong>for spectroscopic <\/strong><strong>studies<\/strong><\/h1>[\/et_pb_text][et_pb_divider color=&#8221;#215500&#8243; divider_weight=&#8221;2px&#8221; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;-23px||6px||false|false&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_divider][et_pb_text _builder_version=&#8221;4.22.1&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;||0px|||&#8221; global_colors_info=&#8221;{}&#8221;]<p align=\"justify\">The HT-IRS 01 reactor is an extension of spectrometers working in infrared. Its universal design makes it fully compatible with all commercially available IR spectrometers. The reactor for spectroscopic research is characterized by a wide range of sample activation and operating temperatures, and it enables measurements to be carried out both in vacuum conditions and in the flow of gases.<\/p>\n<p>Moreover, the reactor can be extended with a plasma generation system. This additional system allows for effective cleaning and plasma activation of the sample.<\/p>\n<p>More information about the reactor construction and principle of operation is included in <a href=\"https:\/\/measline.com\/index.php\/en-gb\/brochure-for-download\/\" target=\"_blank\" rel=\"noopener\"><strong>the brochure for download<\/strong><\/a>.<\/p>\n<p>The device is covered by patent protection: <a href=\"https:\/\/ewyszukiwarka.pue.uprp.gov.pl\/search\/pwp-details\/P.420392?lng=pl\" target=\"_blank\" rel=\"noopener\"><b>Pat.232633<\/b><\/a><\/p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; background_color=&#8221;rgba(0,0,0,0.05)&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row column_structure=&#8221;2_3,1_3&#8243; admin_label=&#8221;Wiersz&#8221; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;-5px|auto||auto||&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;2_3&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.22.1&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;-50px||||false|false&#8221; custom_padding=&#8221;0px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;]<div>\n<h3 class=\"Standard\">The most significant device features:<\/h3>\n<\/div>\n<div>\n<ul>\n<li class=\"Standard\">Total chemical passivity &#8211; chamber made of quartz<\/li>\n<li class=\"Standard\">Easy combination with other analytical methods like gas chromatography and mass or spectroscopic analysis of reaction products<\/li>\n<li class=\"Standard\">Wide range of sample activation temperatures: from room temperature to 1000K<\/li>\n<li>Wide operating temperature range: 100 \u2013 1000K<\/li>\n<li>Ability to carry out experiments in vacuum conditions and gas flow<\/li>\n<li>Easy assembly and disassembly when changing samples or cleaning the chamber<\/li>\n<li>Possibility of extending the reactor with a plasma generation system enabling plasma cleaning and plasma activation of the sample<\/li>\n<li>Parameters of plasma interaction with the sample are regulated by changing the voltage amplitude, frequency, and pressure in the reactor.<\/li>\n<\/ul>\n<\/div>[\/et_pb_text][\/et_pb_column][et_pb_column type=&#8221;1_3&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_gallery gallery_ids=&#8221;1619,1620,1621,1622&#8243; fullwidth=&#8221;on&#8221; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; width=&#8221;98.4%&#8221; min_height=&#8221;137.6px&#8221; custom_margin=&#8221;-50px|||||&#8221; custom_padding=&#8221;0px||0px|||&#8221; animation_style=&#8221;fade&#8221; auto=&#8221;on&#8221; auto_speed=&#8221;5000&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_gallery][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;30px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;0px||0px||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.22.1&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<div class=\"dataTables_scrollHead\">\n<div class=\"dataTables_scrollHeadInner\">\n<h3>Specification:<\/h3>\n<div>\n<table border=\"1\" style=\"border-collapse: collapse; width: 100%; height: 154px;\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 43.6926%; height: 24px;\">The material from which the chamber is made<\/td>\n<td style=\"width: 56.3074%; height: 24px;\">quartz &#8211; ensuring chemical passivity<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 43.6926%; height: 24px;\">Chamber tightness<\/td>\n<td style=\"width: 56.3074%; height: 24px;\">10\u02c9\u2079 mbar*l\/s in the helium test<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 43.6926%; height: 24px;\">Sample activation temperature<\/td>\n<td style=\"width: 56.3074%; height: 24px;\">from room temperature to 1000K<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 43.6926%; height: 24px;\">Working temperature<\/td>\n<td style=\"width: 56.3074%; height: 24px;\">100 \u2013 1000K<\/td>\n<\/tr>\n<tr style=\"height: 10px;\">\n<td style=\"width: 43.6926%; height: 10px;\">Chamber dead volume<\/td>\n<td style=\"width: 56.3074%; height: 10px;\">\n<p align=\"left\">&lt; 1 cm\u00b3<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 43.6926%; height: 24px;\">Dimensions (width x height x depth)<\/td>\n<td style=\"width: 56.3074%; height: 24px;\">reactor: 190 x 180 x 180 mm<br \/>temperature controller: 342 mm x 180 mm x 140 mm<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 43.6926%; height: 24px;\">Temperature controller<\/td>\n<td style=\"width: 56.3074%; height: 24px;\">\n<p align=\"justify\">TCT 02 Temperature controller<br \/>Process temperature controlled manually or by software<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div>\n<ul><\/ul>\n<\/div>\n<div>\n<ul><\/ul>\n<\/div>\n<\/div>\n<\/div>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]\n","protected":false},"excerpt":{"rendered":"<p>The HT-IRS 01 Reactor for spectroscopic studiesThe HT-IRS 01 reactor is an extension of spectrometers working in infrared. Its universal design makes it fully compatible with all commercially available IR spectrometers. The reactor for spectroscopic research is characterized by a wide range of sample activation and operating temperatures, and it enables measurements to be carried [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":1615,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"project_category":[],"project_tag":[],"class_list":["post-4652","project","type-project","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Reactor for spectroscopic studies - Measline projects<\/title>\n<meta name=\"description\" content=\"Reactor for spectroscopic studies adapted to all commercially available IR spectrometers working in transmission mode.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/measline.com\/index.php\/en-gb\/project\/the-ht-irs-01-reactor-for-spectroscopic-studies\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reactor for spectroscopic studies - Measline projects\" \/>\n<meta property=\"og:description\" content=\"Reactor for spectroscopic studies adapted to all commercially available IR spectrometers working in transmission mode.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/measline.com\/index.php\/en-gb\/project\/the-ht-irs-01-reactor-for-spectroscopic-studies\/\" \/>\n<meta property=\"og:site_name\" content=\"Measline\" \/>\n<meta property=\"article:modified_time\" content=\"2023-09-11T06:42:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/measline.com\/wp-content\/uploads\/2022\/01\/DSC_3491-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2464\" \/>\n\t<meta property=\"og:image:height\" content=\"1632\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minuty\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/measline.com\\\/index.php\\\/en-gb\\\/project\\\/the-ht-irs-01-reactor-for-spectroscopic-studies\\\/\",\"url\":\"https:\\\/\\\/measline.com\\\/index.php\\\/en-gb\\\/project\\\/the-ht-irs-01-reactor-for-spectroscopic-studies\\\/\",\"name\":\"Reactor for spectroscopic studies - Measline projects\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/measline.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/measline.com\\\/index.php\\\/en-gb\\\/project\\\/the-ht-irs-01-reactor-for-spectroscopic-studies\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/measline.com\\\/index.php\\\/en-gb\\\/project\\\/the-ht-irs-01-reactor-for-spectroscopic-studies\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/measline.com\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/DSC_3491-1.jpg\",\"datePublished\":\"2023-09-08T12:32:00+00:00\",\"dateModified\":\"2023-09-11T06:42:04+00:00\",\"description\":\"Reactor for spectroscopic studies adapted to all commercially available IR spectrometers working in transmission mode.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/measline.com\\\/index.php\\\/en-gb\\\/project\\\/the-ht-irs-01-reactor-for-spectroscopic-studies\\\/#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/measline.com\\\/index.php\\\/en-gb\\\/project\\\/the-ht-irs-01-reactor-for-spectroscopic-studies\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/measline.com\\\/index.php\\\/en-gb\\\/project\\\/the-ht-irs-01-reactor-for-spectroscopic-studies\\\/#primaryimage\",\"url\":\"https:\\\/\\\/measline.com\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/DSC_3491-1.jpg\",\"contentUrl\":\"https:\\\/\\\/measline.com\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/DSC_3491-1.jpg\",\"width\":2464,\"height\":1632,\"caption\":\"Reaktor do bada\u0144 spektroskopowych HT-IRS 01\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/measline.com\\\/index.php\\\/en-gb\\\/project\\\/the-ht-irs-01-reactor-for-spectroscopic-studies\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Strona g\u0142\u00f3wna\",\"item\":\"https:\\\/\\\/measline.com\\\/index.php\\\/pl\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Projekty\",\"item\":\"https:\\\/\\\/measline.com\\\/index.php\\\/project\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"The HT-IRS 01 Reactor for spectroscopic studies\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/measline.com\\\/#website\",\"url\":\"https:\\\/\\\/measline.com\\\/\",\"name\":\"Measline\",\"description\":\"Advanced solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/measline.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/measline.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/measline.com\\\/#organization\",\"name\":\"Measline\",\"url\":\"https:\\\/\\\/measline.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/measline.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/measline.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/logo_color_small.png.png\",\"contentUrl\":\"https:\\\/\\\/measline.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/logo_color_small.png.png\",\"width\":1000,\"height\":417,\"caption\":\"Measline\"},\"image\":{\"@id\":\"https:\\\/\\\/measline.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Reactor for spectroscopic studies - Measline projects","description":"Reactor for spectroscopic studies adapted to all commercially available IR spectrometers working in transmission mode.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/measline.com\/index.php\/en-gb\/project\/the-ht-irs-01-reactor-for-spectroscopic-studies\/","og_locale":"pl_PL","og_type":"article","og_title":"Reactor for spectroscopic studies - Measline projects","og_description":"Reactor for spectroscopic studies adapted to all commercially available IR spectrometers working in transmission mode.","og_url":"https:\/\/measline.com\/index.php\/en-gb\/project\/the-ht-irs-01-reactor-for-spectroscopic-studies\/","og_site_name":"Measline","article_modified_time":"2023-09-11T06:42:04+00:00","og_image":[{"width":2464,"height":1632,"url":"https:\/\/measline.com\/wp-content\/uploads\/2022\/01\/DSC_3491-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Szacowany czas czytania":"4 minuty"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/measline.com\/index.php\/en-gb\/project\/the-ht-irs-01-reactor-for-spectroscopic-studies\/","url":"https:\/\/measline.com\/index.php\/en-gb\/project\/the-ht-irs-01-reactor-for-spectroscopic-studies\/","name":"Reactor for spectroscopic studies - Measline projects","isPartOf":{"@id":"https:\/\/measline.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/measline.com\/index.php\/en-gb\/project\/the-ht-irs-01-reactor-for-spectroscopic-studies\/#primaryimage"},"image":{"@id":"https:\/\/measline.com\/index.php\/en-gb\/project\/the-ht-irs-01-reactor-for-spectroscopic-studies\/#primaryimage"},"thumbnailUrl":"https:\/\/measline.com\/wp-content\/uploads\/2022\/01\/DSC_3491-1.jpg","datePublished":"2023-09-08T12:32:00+00:00","dateModified":"2023-09-11T06:42:04+00:00","description":"Reactor for spectroscopic studies adapted to all commercially available IR spectrometers working in transmission mode.","breadcrumb":{"@id":"https:\/\/measline.com\/index.php\/en-gb\/project\/the-ht-irs-01-reactor-for-spectroscopic-studies\/#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/measline.com\/index.php\/en-gb\/project\/the-ht-irs-01-reactor-for-spectroscopic-studies\/"]}]},{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/measline.com\/index.php\/en-gb\/project\/the-ht-irs-01-reactor-for-spectroscopic-studies\/#primaryimage","url":"https:\/\/measline.com\/wp-content\/uploads\/2022\/01\/DSC_3491-1.jpg","contentUrl":"https:\/\/measline.com\/wp-content\/uploads\/2022\/01\/DSC_3491-1.jpg","width":2464,"height":1632,"caption":"Reaktor do bada\u0144 spektroskopowych HT-IRS 01"},{"@type":"BreadcrumbList","@id":"https:\/\/measline.com\/index.php\/en-gb\/project\/the-ht-irs-01-reactor-for-spectroscopic-studies\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Strona g\u0142\u00f3wna","item":"https:\/\/measline.com\/index.php\/pl\/"},{"@type":"ListItem","position":2,"name":"Projekty","item":"https:\/\/measline.com\/index.php\/project\/"},{"@type":"ListItem","position":3,"name":"The HT-IRS 01 Reactor for spectroscopic studies"}]},{"@type":"WebSite","@id":"https:\/\/measline.com\/#website","url":"https:\/\/measline.com\/","name":"Measline","description":"Advanced solutions","publisher":{"@id":"https:\/\/measline.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/measline.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/measline.com\/#organization","name":"Measline","url":"https:\/\/measline.com\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/measline.com\/#\/schema\/logo\/image\/","url":"https:\/\/measline.com\/wp-content\/uploads\/2021\/11\/logo_color_small.png.png","contentUrl":"https:\/\/measline.com\/wp-content\/uploads\/2021\/11\/logo_color_small.png.png","width":1000,"height":417,"caption":"Measline"},"image":{"@id":"https:\/\/measline.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/measline.com\/index.php\/wp-json\/wp\/v2\/project\/4652","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/measline.com\/index.php\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/measline.com\/index.php\/wp-json\/wp\/v2\/types\/project"}],"author":[{"embeddable":true,"href":"https:\/\/measline.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/measline.com\/index.php\/wp-json\/wp\/v2\/comments?post=4652"}],"version-history":[{"count":9,"href":"https:\/\/measline.com\/index.php\/wp-json\/wp\/v2\/project\/4652\/revisions"}],"predecessor-version":[{"id":4744,"href":"https:\/\/measline.com\/index.php\/wp-json\/wp\/v2\/project\/4652\/revisions\/4744"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/measline.com\/index.php\/wp-json\/wp\/v2\/media\/1615"}],"wp:attachment":[{"href":"https:\/\/measline.com\/index.php\/wp-json\/wp\/v2\/media?parent=4652"}],"wp:term":[{"taxonomy":"project_category","embeddable":true,"href":"https:\/\/measline.com\/index.php\/wp-json\/wp\/v2\/project_category?post=4652"},{"taxonomy":"project_tag","embeddable":true,"href":"https:\/\/measline.com\/index.php\/wp-json\/wp\/v2\/project_tag?post=4652"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}